Redox Meter - ORP meter

F0404401
€439.11
€362.90 tax excl.
Delivery 2 to 3 weeks

The ORP meter is a hand held meter which is characterised by measuring ORP values, pH and analyses the temperature.

The delivery of the temperature meter includes 6 x 1.5 V batteries. 

Dimensions: 177 x 68 x 45 mm.

Thermometer

Electricity

Monitoring

 

The hand-held ORP (mV) meter used to measure pH and ambient temperature. In addition, it has a large, easy-to-read LCD display. 

The values of the temperature meter can be stored directly on the SD memory card or can be sent to the computer via RS-232 interface. Software and RS-232 data cable are also available as optional items. 

Temperature compensation can be done manually or automatically via a sensor included in the delivery. An additional pH electrode PE-03 is required to determine the pH value.

The delivery of the temperature or pH meter contains:

  • 1 ORP meter PCE-228 R
  • 1 ORP-14 electrode
  • 1 SD memory card (2 GB)
  • 1 Temperature sensor
  • 1 Instruction manual
Redox Range
-1999 ... 0 ... 1999 mV
Redox resolution
1 mV
Redox precision
±(0,5 % + 2d)
pH range
0,00 ... 14.00 pH (only with optional pH electrode)
pH resolution
0,01 pH
pH accuracy
±(0,02 pH + 2d)
Temperature Range
0.0...65.0 °C (only temperature sensor)
Temperature Resolution
0,1 °C
Temperature Accuracy
±0,5 °C
Calibration
Automatic three-point
Temperature Compensation
Automatic from 0 ... 65°C or manual between 0 and 100°C by removing the temperature sensor
Electrode
ORP-14 ORP-14 ORP electrode, cable length 1m and BNC connector
Measurement fee
Adjustable from 1 second up to 8 hours 59 min. 59 sec.
Display
52 x 38 mm LCD
Port
RS-232
Software
Optional
Power supply
6 x 1.5 V batteries, type AA / 9 V mains adapter (optional)
Environmental conditions
0...50 °C max..85 % R.H.
Weight
490 g
Dimensions
177 x 68 x 45 mm
Storage
SD card 1 ... 16 GB