Magnetometer - Electrostatic Field Meter

F0403501
€1,191.73
€984.90 tax excl.
Delivery 2 to 3 weeks

The magnetometer is an electromagnetic meter that is used to monitor the electrostatic charge on surfaces, the human body and objects. In addition to electrostatic electricity, this radiation meter also measures ambient humidity and temperature. 

Dimensions: 123 x 70.4 x 21.5 mm. 

Humidity Temperature
Monitoring Antistatic Electricity and waves ondas

Exclusive gift!

Get a gift bag for purchases over 300€.

 

The radiation meter has a measuring range of approximately 60kV DC.

Static electricity is the build-up of excess electrical charge on either an insulating or conductive material. Static charge generated on surfaces can cause damage to electronic parts and other objects. In case of high electrostatic charge, and in contact with inflammable gases or liquids, a flame or fire can occur.

Magnetometers are normally used in manufacturing and ESD (Elctrostatic Discharge) rooms. 

The electromagnetic field meter is powered by a 9 V battery and has a maximum autonomy of 20 hours. The magnetometer is also supplied with two lasers which control the measuring distance.

The device is switched off after 5 minutes of inactivity. 

The radiometer is delivered with:

  • 1 Electrostatic field strength meter PCE-SFS 10
  • 1 Earthing cable
  • 1 Carrying case
  • 1 9 V Battery
  • 1 Instruction manual

It weighs 147 grams. 

Temperature measuring range
-40 ... 123,8 °C
Temperature Resolution
0,1 °C
Temperature Accuracy
±1,5 °C
Power supply
9 V block battery
Environmental conditions
0 ... 40 °C / 32 ... 104 °F, 0 ... 60% RH, non-condensing
Weight
147 g
Dimensions
123 x 70,4 x 21,5 mm
Response time
less than 100 ms
Automatic shutdown
after 5 minutes
Battery life
more than 20 hours
Humidity resolution
0,1 % H.r.
Humidity accuracy
±4,5 % H.r.
Electromagnetic field measuring range
±60 kV DC
Electromagnetic field resolution
+20 ... +60 kV DC: 0,1 kV DC
-60 ... -20 kV DC
±20 kV DC: 0,01 kV DC
Electromagnetic field accuracy
±5 % of measured value
Humidity measuring range
0 ... 100 % H.r.
Acoustic alarm
5 seconds before the automatic shutdown,
when switching on the measuring device,
when the measuring range is exceeded